Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 08/08/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND WASTE & VENT THRU BUILDING AND HCS OK 1. RECALL 03005 FOR INSPECTION PRIOR TO CONCRETE POUR 2. ALL BRANCHES MORE THAN 5' FROM MAIN BUILDING DRAIN REQUIRE FULL SIZE UPPER TERMINAL CLEANOUTS |
|
| 08/06/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/02/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* TOO WET FOR WATER TEST - EXPOSE ALL FITTINGS & PIPING PROVIDE DRY MATERIAL FOR BEDDING & SHADING |