Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/11/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO INSULATE BLDG. |
|
| 10/10/2007 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED |
|
| 10/02/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PLANS & 2003 IECC REQUIRE R8 DUCT IN THE ATTIC - PLANS REQUIRE 1/2" THICK INSULATION ON REFER LINES - REMOVE SCREENS FROM DRYER VENTS - PROVIDE TRAPS ON CONDENSATE DRAIN LINES - USE PRIMER ON ALL PVC FITTINGS - SCREW EXHAUST DUCTS TO FAN OUTLETS - SUPPORT REFER LINES AT PENETRATION THRU PLATES |