Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T07CM01697
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
08/08/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST THRU BUILDING & HCS UNDERGROUND OK 1. RECALL 03005 FOR INSPECTION PRIOR TO CONCRETE POUR 2. ALL BRANCHES OVER 5' FROM MAIN BUILDING DRAIN REQUIRE FULL SIZE UPPER TERMINAL CLEANOUTS. |
|
08/06/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
08/02/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* - TOO WET FOR WATER TEST. - EXPOSE ALL FITTINGS & PIPING - PROVIDE DRY MATERIAL FOR BEDDING & SHADING |
|
07/26/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* SITE SEWER DISCUSSION, SHALL HAVE CITY APPROVED SITE PLAN OF ACTUAL SEWER INSTALLATION ON SITE. |