Date Description Inspector Results Comments
08/01/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/30/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
FROM LAST INSP CLIP EACH END OF SHEAR 2ND FLOOR
NEED REVISED TRUSS DRAWINGS
07/26/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED 5 A35 CLIPS AT SHEARWALL 2ND FLOOR WALL TO DRAG TRUSS
2) NAIL OFF WIND BRACE 2ND FLOOR NORTH WALL
3) NAIL PANELS (BETWEEN TRUSSES) TO ROOF 90A/SD3 ABOVE 1ST FLOOR POWDER ROOM
4) DIG TRUSS FRONT 2ND FLOOR, DRAWINGS SHOW DBL T/CHORD