Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01681
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/30/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* FROM LAST INSP CLIP EACH END OF SHEAR 2ND FLOOR NEED REVISED TRUSS DRAWINGS |
|
| 07/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED 5 A35 CLIPS AT SHEARWALL 2ND FLOOR WALL TO DRAG TRUSS 2) NAIL OFF WIND BRACE 2ND FLOOR NORTH WALL 3) NAIL PANELS (BETWEEN TRUSSES) TO ROOF 90A/SD3 ABOVE 1ST FLOOR POWDER ROOM 4) DIG TRUSS FRONT 2ND FLOOR, DRAWINGS SHOW DBL T/CHORD |