Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM01656
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/06/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER ALL AREAS 2. NEED TO SEE CLOSET FLANGE |
|
08/23/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - PLAN NOT APPROVED - A BELL REDUCER IS NOT AN INDIRECT WASTE RECEPTACLE - DESIGN DOES NOT MEET THE STANDARD FOR A STAND PIPE RECEPTOR. |
|
08/20/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN 2) PLANS DOES NOT SHOW TERMINATION OF PAIR DRAIN, T & P RELIEF DRAIN AND CONDENSATE WASTE, STAND PIPE IS NOT APPROVED RECEPTOR |