Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM01655
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
11/08/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
10/24/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV THRU ROOF SEAFOOD/MEAT AREA WATER TEST OK WATER PIPING IN WALL OK WILL SEE OVERHEAD WATER AT LATER DATE |
|
10/04/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF AGUA FRESCAS WITH WATER PIPING IN WALL & OVERHEAD OK SHALL FINISH OVERHEAD INSULATION |
|
10/03/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RECEIVED (2) BACKFLOW CERTIFICATIONS FOR OVER & PROOFER WATER TEST THRU ROOF FLORAL DWV AND BAKERY HANDSINK & FLOOR SINK VENTS OK - WATER PIPING THESE 2 AREAS OK |
|
10/02/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER SUPPLY TO PROOFER & OVEN WITH BACKFLOW DEVICES OK -- NEED CERTIFICATIONS FOR (2) BACKFLOW DEVICES THIS AREA. |
|
09/11/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* VTRS AT DAIRY COOLER NEAR COL E.6 OK FS AT BAKERY PREP W/VTR AND REVENT FROM OTHER FS OK INSTALL FS AND FOAM WRAPS 2" CW NEAR COL 7 OK RECHECK AFTER CEILING GRID FOR ISOLATION FROM METAL WATER MAINS BETWEEN COLS 12 & 13 OK WATER LINE BRANCH PIPING BETWEEN COLS B-D AND COLS 11 &13 OVERHEAD & OK FOR INSULATION. HANGERS NOT TO EXCEED 6' |
|
08/28/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT DELI IN WALL THRU ROOF CONNECT TO EXISTING OK WATER PIPING IN WALL ONLY OK DELI AREA |
|
08/22/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
08/20/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CLOSET FLANGE PHARMACY OK |
|
08/08/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* VENT THRU ROOF WATER TEST AT DELI SINK & FLOOR SINK OK WATER PIPING TO ABOVE CEILING AT DELI SINK OK VENT THRU ROOF 3" AND (1) 2" FOR GREASE INTERCEPTOR WATER TEST OK TEMP. CAP VENT AT PRODUCE PREP OR TERMINATE THRU ROOF NOW! |
|
08/06/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PHARMACY RESTROOM & SINK AREA WATER PIPING PER REVISED YET TO BE APPROVED PLAN ON SITE DATED 6/26/07 CHRISTOPHER MARONEY P.E ALL REDLINES & REVISED APPROVED PLAN SHOWING REDLINE CHANGES SHALL BE ON SITE FOR FINAL |
|
07/26/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE VACUUM BREAKERS ON HOSE BIBS IN RESTROOMS 2. SHALL PROVIDE A MEANS TO CONTROL HOT WATER TEMP. BESIDES WATER HEATER AT PUBLIC USE LAVS. |
|
07/24/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES RESTROOM 120, 121 OK |
|
07/18/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - WASTE & VENT FOR PRODUCE PREP AREA WATER TEST THRU ROOF -- OK - WATER PIPING PRODUCE PREOP TO 10' A.F.F AIR TEST OK |
|
07/13/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF, AIR TEST WATER PIPING TO ABOVE CEILING RESTROOMS 120, 121 OK |
|
07/11/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST FROM WEST EDGE OF BUILDING 4" GW INTO INTERCEPTOR THRU INTERCEPTOR WITH 2" VENT AND 4" SANITARY DRAIN TIE IN TO EXISTING PER REDLINE OK |
|
07/10/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WASTE & VENT THRU ROOF & WATER PIPING BREAKROOM & MOP SINK COLUMN LINE 10 -- OK |