07/18/2007 | BUILDING - PROGRESS | Approved | IVRS - Inspection :* 7 - FOOTING EXCAVATIONS W/REINFORCING STEEL FOR CANTILEVER PARKING SHADE STRUCTURE AS PER ENGINEERS STAMPED DRAWING FOR SPREAD FOOTINGS. |
|
07/17/2007 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* NO PLANS OR PERMIT ON SITE |
|
07/05/2007 | BUILDING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* COLUMNS EXCAVATIONS ARE NOT DEEP ENOUGH MUST BE RE-CALC'ED & SUBMITTED |
|