Permit: T07CM01633

Parcel: 107144300


Addresses:

2569 N 1ST AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/24/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
06/18/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER WALLS, BATH HARD LIDS
06/13/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) USE PROPER CRIMP TOOL FOR CRIMP SLEEVES NEC 110.3 B
2) PROVIDE NAIL PLATES 1 1/4 OR LESS FROM STUD FACE NEC 300.4
3) SEAL UNUSED OPENINGS IN BOXES NEC 314.17 A
4) ELECTRICAL NOTES ARE FOR A RESIDENCE, NOT COMMERCIAL-REVISE TO SHOW ACTUAL SCOPE OF WORK AND WIRING METHOD
5) GROUND ALL METAL BOXES, GROUND TO WRAP MINIMUM 2/3 RDS AROUND SCREW AND TIGHTEN NEC 250.4
6) INSTALL ALL MUD RINGS
7) WIRING NOT COMPLETE/HANGING WIRES
8) WATER BOND CLAMP TO BE ACCESSIBLE
9) IDENTIFY WHITE USED AS HOT IN SWITCH LEGS NEC 200
10) WIRING NOT PER PLAN
11) WORK TO BE DONE BY ELECTRICAL CONTRACTOR