Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01626
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/27/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 4, 6, 7 & 8 FROM 6/21/07 NOT COMPLETED |
|
06/22/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO REPAIRS MADE FROM 6/21/07 INSPECTION 2) NEXT FAILURE WILL REFEE |
|
06/21/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO GAS TEST-TO LOW 2) SUPPORT HORIZONTAL DWV AT 4 FT ON CENTER 3) STAIR WINDER MUST BE 6" ON NARROW END 4) FIRE BLOCK STAIRS 5) NO DWV TEST 6) INSULATE BEHIND TUBS 7) REMOVE DEAD HEAD M/LAV PLUMBING OR PROVIDE PROOF OF PAYMENT OF SEWER FEE 8) FIRE STOP 1/2 BATH CHASE 9) BLOCK COMBUSTION AIR |