Permit: T07CM01599

Parcel: 121060730


Addresses:

5601 E MABEL ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
05/17/2007 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
PROVIDE APPROVED PIPING CPVC, COPPER FOR T&P TO DAYLIGHT AND 90 DEG. DOWN 6" TO 24" OFF GRADE AND CALL BACK FOR FINAL
04/27/2007 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE OLD PIPING FROM OLD METER LOCATION, DROP NEW PIPE DOWN TO WATER HEATER LOCATION.
2. INSTALL FLASHING AT ROOF PENETRATIONS
RETEST SYSTEM
3. PIPE T&P RELIEF DRAIN TO EXTERIOR, TERMINATE 6" ABOVE GROUND, USE MATERIALS APPROVED FOR HW.
4. INSTALL TYPE B VENT AT WH VENT PENETRATION THROUGH CEILING AND ROOF. TERMINATE W/LISTED B VENT CAP.
5. CAP UNUSED VALVE AT DRYER.
04/24/2007 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection NOBODY HOME