Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01574
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/19/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - FILL ALL HOLES IN FHA PLATE ON 2X6 BATHROOM SHEAR WALL. - ANCHOR BOLT NEEDED IN 2X6 SHEAR WALL OF BATHROOM - DRAFTSTOP TUB AT FLOOR - SEAL HOLES IN FIRESTOP OF FRONT HALL ENTRY - NAIL DOWN SOLE PLATE FOR UPSTAIRS 2X6 BATHROOM SHEAR WALL TO PLANS - NAIL OFF HANGERS FOR RAFTERS ABOVE STAIRWAY - NAIL OFF GYPSUM SHEARWALL SOLE PLATES TO PLAN |