Permit: T07CM01574

Parcel: 141350200

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01574

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2007 FRAMING Approved IVRS - Inspection :*
06/19/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- FILL ALL HOLES IN FHA PLATE ON 2X6 BATHROOM
SHEAR WALL.
- ANCHOR BOLT NEEDED IN 2X6 SHEAR WALL OF BATHROOM
- DRAFTSTOP TUB AT FLOOR
- SEAL HOLES IN FIRESTOP OF FRONT HALL ENTRY
- NAIL DOWN SOLE PLATE FOR UPSTAIRS 2X6 BATHROOM SHEAR WALL TO PLANS
- NAIL OFF HANGERS FOR RAFTERS ABOVE STAIRWAY
- NAIL OFF GYPSUM SHEARWALL SOLE PLATES TO PLAN