Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/04/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/10/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 12X12 FOOTERS REQUIRED PORCH POSTS 2. COMPLY WITH DETAIL 5/S1 EXTERIOR WALLS & FOOTERS 3. WINDOWS NOT PER APPROVED PLAN 4. EXPOSE BOTTOM PLATES TO VERIFY TREATED LUMBER 5. REFASTEN ALL SIDING 6. INSTALL SMOKIES ALL BEDROOMS |
|
| 12/07/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SYSTEM DOWN UNABLE TO GET MESSAGE 2) NO ANSWER AT DOOR 3) NO PLANS |