Permit: T07CM01552

Parcel: 136251980


Addresses:

6665 E 42ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/12/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/11/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CONNECT WIRES IN CAN LIGHTS
2) USE ROMEX CONNECTORS WHERE WIRES ENTER CAN LIGHTS
07/02/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE ALL ROMEX/TERMINATE INTO BOX
2) GROUND ALL METAL BOXES
3) RECHECK ALL BOXES NEED MORE FREE CONDUCTORS IN BOX 6" TO 9"
4) TERMINATE CONDUCTORS INTO RECESSED LIGHT BOX AND WIRE NUTS
5) ALL JUNCTION BOXES-NEED TO BE READILY ACCESSIBLE
6) TERMINATE ROMEX FOR DRYER CIRCUIT INTO A BOX