Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM01541

Parcel: 141314620

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01541

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/22/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) WILL CHECK AT INTERMEDIATE-BLOCK OSB FRONT POP OUT DECK BLOCK JOINT AND OSB TURNED OPPOSITE TRUSS
05/16/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FRONT ROOF POP OUT OSB TURNED WRONG WAY BLOCK EDGES
2) TWO NAIL IN EACH WIND BRACE AT ALL PLATES
3) FRONT COL. POP OUTS BEAR BETWEEN TRUSSES BLOCK FOR SUPPORT UNDER COLUMNS.
4) A3.5 AT TOP OF DBL TOP PLATE FRIEZE BOARDS. DRIVE NAILS HOME