Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01540
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/26/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HD8A NUTS AT GARAGE LOOSE 2) BANG PLATES WRITTEN ON FLOOR 3) NAIL DOWN MISSED FOR JOINTS 4) DWV POTABLE H20 TEST/REQUIRED 5) CHECK ALL SHEARWALL PLATES AND MISSED INTERIOR BOTTOM PLATES FOR NAILING 6) STILL INSTALLING STUCCO 7) MISSING A.B.'S AT SHEAR |