Permit: T07CM01525

Parcel: 141093480


Addresses:

6538 E BRUSHBACK LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/03/2007 FRAMING Approved IVRS - Inspection :*
07/02/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTHING FROM PRIOR INSPECTIONS COMPLETED
06/27/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREPLACE METAL SAFETY STAIRS NOT INSTALLED
2) COMBUSTIBLE MATERIAL NOT ALLOWED WITHIN 45 DEGREES OF FIREPLACE OPENING ON SIDE PAGE 4 OF MANUAL
3) HOLDOWN MISSING INTERIOR SHEARWALL 5
4) STAIR PONY WALL MUST BE CAPABLE OF SUPPORTING 200 POUND SIDE LOAD
5) FIREBLOCK STAIRS AND STAIR CHASE