Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM01519

Parcel: 134163550

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/29/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/25/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CUT VIEW HOLES IN FRONT COLUMNS
2) STRAP NON-CABIN TIED FRONT TOP PLATES
3) NAIL ALL STUDS IN WEST SIDE SHEAR PANEL-1ST FLOOR SOUTH END