Permit: T07CM01494

Parcel: 11619077A


Addresses:

300 W PASEO REDONDO


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01494

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/09/2007 FRAMING Approved IVRS - Inspection :*
06/19/2007 FRAMING Partial Approval IVRS - Inspection :*
PENDING REVISION
06/18/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
06/15/2007 FRAMING Partial Approval IVRS - Inspection :*
1) RFI NEED TO BE APPROVED BY DSD CITY OF TUCSON-NEW REVISION FOR ANY CHANGES ON APPROVED PLANS. THIS INSPECTION COVER CONFERENCE ROOM FRAMING ALSO RESTROOMS ON 2ND FLOOR
06/08/2007 FRAMING Partial Approval IVRS - Inspection :*
ALL AREAS EXCEPT 1ST FLOOR RESTROOMS & EAST CONFERENCE WALL -- OK TO SHEETROCK PROGRESS AREAS
06/07/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
MUST PROVIDE AND DISPLAY TEMPORARY ADDRESS NUMBER IN ACCORDANCE WITH PZCO 18.83.050

PROVIDE COLD FORMER STEEL STUDS 24" O.C
PROVIDE SCREW CONNECTIONS ON STUDS AND BOTTOM TRACK, SCREW CONNECTIONS ON DOOR/WINDOW HEADERS, SEPARATION OF STUDS ON FURR OUT WALLS, ON RESTROOMS COMPLETE PLUMBING INTERMEDIATE AND PROVIDE BACKING FOR GRAB BARS IN ACCORDANCE WITH APPROVED PLANS AND SPEC. SECTION 2210 IBC 604.5 ANSI/A117.1 03
06/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
DOORS LOCKED NO ACCESS