Permit: T07CM01484

Parcel: 116033010


Addresses:

2450 W CALLE RETANA

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/15/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/14/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOTTOM HORIZONTAL REBAR NEEDS TO BE LOWERED 3" FROM END OF REBAR TAILS OR ?
2) NEED TO SUPPORT REBAR MAT FROM BRIDGING-MORE CHAIRS
3) NEED TO TIE REBAR AT LEAST 70 PERCENT-HORIZ. LOOSE
4) NEED TO WRAP EXISTING PLUMBING
5) MARK FINISH GRADE ON EXISTING PART OF HOUSE, SO I CAN CHECK FOR 4" THICK SLAB