Permit: T07CM01477

Parcel: 141094120


Addresses:

8016 S VEDDER DR


Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T07CM01477

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
07/02/2007 SHEET ROCK NAILING Approved IVRS - Inspection :*
06/28/2007 SHEET ROCK NAILING Denied IVRS - Inspection :
The drywall is not nailed per code.| 175*
1) NO CHANGE FROM 6/26/07
06/26/2007 SHEET ROCK NAILING Denied IVRS - Inspection :
The drywall is not nailed per code.| 175*
1) GARAGE LID UNDER OCCUPIED SPACE MUST BE SECURED WITH 1 7/8" NAILS OR SCREWS AT 6" ON CENTER PER IRC TABLE 702.3.5 NOTE E DETAIL 8 OF PAGE 1.3 IS WRONG HAVE PLAN REVISED AND APPROVED BY CITY OF TUCSON
2) DRYWALL MUST BE INSTALLED PERPENDICULAR TO TRUSSES AT GARAGE LID
3) OK TO TAPE HOUSE-DO NOT TAPE GARAGE