Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T07CM01477
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/02/2007 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
06/28/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1) NO CHANGE FROM 6/26/07 |
|
06/26/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : The drywall is not nailed per code.| 175* 1) GARAGE LID UNDER OCCUPIED SPACE MUST BE SECURED WITH 1 7/8" NAILS OR SCREWS AT 6" ON CENTER PER IRC TABLE 702.3.5 NOTE E DETAIL 8 OF PAGE 1.3 IS WRONG HAVE PLAN REVISED AND APPROVED BY CITY OF TUCSON 2) DRYWALL MUST BE INSTALLED PERPENDICULAR TO TRUSSES AT GARAGE LID 3) OK TO TAPE HOUSE-DO NOT TAPE GARAGE |