Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01477
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/23/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH DETAIL 4 OF SHEARWALL PAGE BOTH WINDOWS AT NORTH END OF WEST WALL 2) COMPLY WITH DETAIL 4 OF SHEARWALL SCHEDULE FOR BOTH EAST WALL WINDOWS ON SECOND FLOOR 3) EXTEND SHEAR PLATE TO PLATE |