Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM01473
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/26/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEPERATE ALL CONDUCTORS THAT ARE BUNDLED 2) FOAM AND INSULATE CONDUCTORS GOING THRU CMU WALL 3) NEED TO RED LINE 3" VTR TO SHOW 1 1/2" 4) STRAP ALL DUCT VENT TO SUPPORT DUCT 5) SEPERATE CONDUCTOR AT HOME RUNS 6) SMOKE DETECTORS IN BEDROOM AND HALLWAY AND NEED HARD WIRED 7) MAKE UP IN J-BOX HALLWAY NEEDS TO BE COMPLETED |