Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM01447

Parcel: 141350150

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01447

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/14/2007 FRAMING Approved IVRS - Inspection :*
06/12/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FILL ALL NAIL HOLES IN FHA STRAPS
2) DISPERSE GYPSUM LOAD UPSTIARS
3) LTT20B NEEDED SOUTH END OF GARAGE OVERHEAD DOOR WALL
4) 5 ANCHORS NEEDED AT SILL OF SHEARWALL EAST OF PATIO DOOR
5) REHANG FIXTURE IN UPSTAIRS SOUTH CLOSET
6) NAIL PROTECT SOUTH WALL MARKED WITH 2" BACK MASTER BEDROOM
7) NAIL PROTECT GARAGE OUTLET WIRES
06/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DISPERSE GYPSUM LOAD ON 2ND STORY
2) SUPPORT UPSTAIRS GUARD WALL ALONG STAIRWAY
3) BLOCK DUCTWORK MINIMUM 3 SIES
4) LTT20B NEEDED SOUTH END OF GARAGE OVERHEAD DOOR WALL
5) 5 ANCHORS NEEDED AT SILL OF SHEARWALL EAST OF PATIO DOOR
6) NAIL PROTECT OUTSIDE GARAGE OUTLET SOUTH WALL AT TOP PLATE
7) LEAK IN UPSTAIRS BATH DWV
8) SUPPORT ABS MAXIMUM 4' ABOVE NOOK, BELOW UPSTAIRS BATH
9) FINISH DUCT WORK UPSTAIRS
10) FILL ALL HOLES IN FHA STRAPS OF NOTCHED EXTERIOR WALLS WITH 16D NAILS
11) STOPPED INSPECTION