Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01447
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FILL ALL NAIL HOLES IN FHA STRAPS 2) DISPERSE GYPSUM LOAD UPSTIARS 3) LTT20B NEEDED SOUTH END OF GARAGE OVERHEAD DOOR WALL 4) 5 ANCHORS NEEDED AT SILL OF SHEARWALL EAST OF PATIO DOOR 5) REHANG FIXTURE IN UPSTAIRS SOUTH CLOSET 6) NAIL PROTECT SOUTH WALL MARKED WITH 2" BACK MASTER BEDROOM 7) NAIL PROTECT GARAGE OUTLET WIRES |
|
06/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DISPERSE GYPSUM LOAD ON 2ND STORY 2) SUPPORT UPSTAIRS GUARD WALL ALONG STAIRWAY 3) BLOCK DUCTWORK MINIMUM 3 SIES 4) LTT20B NEEDED SOUTH END OF GARAGE OVERHEAD DOOR WALL 5) 5 ANCHORS NEEDED AT SILL OF SHEARWALL EAST OF PATIO DOOR 6) NAIL PROTECT OUTSIDE GARAGE OUTLET SOUTH WALL AT TOP PLATE 7) LEAK IN UPSTAIRS BATH DWV 8) SUPPORT ABS MAXIMUM 4' ABOVE NOOK, BELOW UPSTAIRS BATH 9) FINISH DUCT WORK UPSTAIRS 10) FILL ALL HOLES IN FHA STRAPS OF NOTCHED EXTERIOR WALLS WITH 16D NAILS 11) STOPPED INSPECTION |