Permit: T07CM01446

Parcel: 141350160

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01446

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/12/2007 FRAMING Approved IVRS - Inspection :*
06/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VERY TOP RISER EXCEEDS 7 3/4" MAXIMUM
2) FILL ALL NAIL HOLES IN FHA STRAPS WITH 16D NAILS
3) BLOCK DUCT SUPPLIES 3 SIDES
4) ANCHOR BOLTS MISSING MAIN FLOOR BATH SHEARWALLS
5) SHEAR PANEL NEEDED TO UNDERSIDE OF FLOOR SHEATHING ON MAIN FLOOR SHEAR PANELS
6) FINISH STUCCO MESH
7) NAIL PROTECT UPSTAIRS BEDROOMS
8) FIX LEAK IN UPSTAIRS BATH DRAIN LINE HIT BY STAPLE WEST WALL IN BATHROOM FOR SINK