Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01446
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/12/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VERY TOP RISER EXCEEDS 7 3/4" MAXIMUM 2) FILL ALL NAIL HOLES IN FHA STRAPS WITH 16D NAILS 3) BLOCK DUCT SUPPLIES 3 SIDES 4) ANCHOR BOLTS MISSING MAIN FLOOR BATH SHEARWALLS 5) SHEAR PANEL NEEDED TO UNDERSIDE OF FLOOR SHEATHING ON MAIN FLOOR SHEAR PANELS 6) FINISH STUCCO MESH 7) NAIL PROTECT UPSTAIRS BEDROOMS 8) FIX LEAK IN UPSTAIRS BATH DRAIN LINE HIT BY STAPLE WEST WALL IN BATHROOM FOR SINK |