Permit: T07CM01399

Parcel: 140151250


Addresses:

2125 E HOLLADAY ST


Inspection Status: Denied

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM01399

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Denied

Date Description Inspector Results Comments
11/24/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND METAL BOXES
2) CEILING FAN BOXES REQUIRED
3) MAKE UP ALL SWITCHES PIG TAIL GROUNDS
4) 12-2 AND 14-2 SAME BOX KITCHEN
5) MAKE UP CAN LIGHTS ROMEX CONNECTORS
7) COMPLETE HOMERUNS
11/21/2008 ELECTRIC - INTERMEDIATE Cancelled IVRS - AP canceled
11/15/2007 ELECTRIC - INTERMEDIATE Denied MAKE UP ALL J-BOXES AND WIRING AT RECESSED LIGHTS
EXT LIGHT J BOX MISSING
1/2" EXT BOLTS REQUIRED AT EXTERIOR WALLS PER PLAN. POWER PINS USED
INSTALL DUCTS