Permit: T07CM01388

Parcel: 134100080

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/26/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/30/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
NOTE #1 & #2 FROM 5/10/07 OK

SEE NOTE #3 FROM 5/10/07 AND COMPLY

NOTE: WATER HEATER PAN DRAIN CAN TERMINATE IN A VISIBLE LOCATION, SHALL NOT BE CONNECTED TO BRANCH TAILPIECE OF LAV.
05/10/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE CORRECT DRAIN ARM FOR URINAL DRAINAGE.
2. SHALL PROVIDE WATER HAMMER ARRESTOR FOR URINAL QUICK CLOSING VALVE.
3. SHALL PROVIDE FLOOR DRAINS PER 2003 UPC OR HAVE PETITION OF APPEAL ON SITE.