Inspection History: ELECTRIC - FINAL

Permit Number - T07CM01369

Inspection Description - ELECTRIC - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
06/01/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
04/16/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
04/12/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EACH BEDROOM AND ROOM LOADING TO BEDROOM WILL REQUIRE AN INNER CONNECTED HARD WIRED SMOKE DETECTOR SYSTEM
2) FAN BOXES CANNOT BE SUPPORTED BY DRYWALL SCREWS MUST USE #10 WOOD SCREWS
3) NAIL PROTECT WIRES AND PLUMBING WITHIN 1 1/4" OF STUD WALL SURFACES
4) OUTLET FOR JACUZZI TUB MUST BE ACCESSIBLE
5) YOU MUST PROVIDE AN ACCESS PANEL FOR THE JACCUZI PUMP REPLACEMENT
6) BATHROOM EXHAUST FAN MUST EXHAUST OUTSIDE
7) GROUND METAL FAN BOXES