Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 07/20/2007 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE CORRECT DRAINAGE FITTINGS 2. TAILPIECE LENGTH NOT TO EXCEED MAX. LENGTH 3. TEST TO HAVE NO LEAKAGE 4. VENTS TO HAVE NO BACKPITCH 5. CLOSET FLANGES TO BE SECURED & INSTALLED ON FINISH FLOOR 6. SHALL FIRE STOP PENETRATIONS THRU FLOOR 7. T&P DRAIN TO BE APPROVED MATERIAL 8. SHALL VIEW DEMO CAPS 9. WATER HEATER TO HAVE HEAT TRAPS OR HEAT TRAP NIPPLES WITH 8" INSULATION IN & OUT OF WATER HEATER PER 2003 IECC BREAKROOM WATER TEST DWV THRU ROOF OK WATER PIPING OK BREAKROOM ONLY |
|
| 07/19/2007 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* |