Permit: T07CM01343

Parcel: 141097260

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01343

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/25/2007 FRAMING Approved IVRS - Inspection :*
06/21/2007 FRAMING Partial Approval IVRS - Inspection :*
1) WATER HEATER B-VENT MUST HAVE A VERTICAL RISER OF 30 DEGREES MINIMUM. PRESENTLY ONLY 20 DEGREE PITCH. SEE IRC G 2427.6.4
2) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
06/19/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) (MECHANICAL)
2) SUPPORT 1 1/2 ABS CEILING POWDER ROOM
3) ADJUSTABLE 90 DEGREE ON WATE HEATER B-VENT