Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM01337
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/08/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2, 5 & 7 NOT DONE |
|
07/30/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) WATER HEATER VENT MUST EXTEND 12" ABOVE ROOF TO BOTTOM OF CAP 2) GAS VENT DRIP RINGS NOT PROPERLY INSTALLED 3) WATER METER FULL OF DIRT 4) GAS VENT WEATHER CAPS NOT PROPERLY INSTALLED 5) DISHWASHER DRAIN NOT INSTALLED 6) REVERSE PITCH A/C SECONDARY 7) NAIL PROTECT PEX AT FAU PLATFORM |