Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM01337

Parcel: 141097100

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01337

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/31/2007 FRAMING Approved IVRS - Inspection :*
05/23/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER KEN