Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/22/2007 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Items 5 & 8 from prior inspections not done |
|
| 06/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 4, 5, 6, 8 & 12 FROM 6/18/07 NOT DONE 2) PLUMBING APPROVED IN ERROR ON 6/18/07-NOW DENIED SEE ITEM 5 |
|
| 06/18/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REDHEAD ANCHOR BOLTS LOOSE IN GARAGE 2) DINING ROOM SMALL SHEARWALL REQUIRES 2 ANCHOR BOLTS 3) STUDS NOT BEARING ON SILL PLATE DINING ROOM 4) BLOCK DUCT BOOTS 3 SIDES 5) KITCHEN TRAP WEIR CANNOT BE HIGHT THAN VENT OPENING 6) SEAL 2ND FLOOR TUB PENETRATIONS 7) NO SECOND FLOOR DWV TEST 8) NO INSULATION BEHIND TUBS 9) MISSING DUCT WORK 10) BLOCK DUCT BOOTS 3 SIDES 11) FIRESTOP STAIRS 12) FIRESTOP 1/2 BATH CHASE 13) OVERSPAN STUD MISSING L/R |