Permit: T07CM01336

Parcel: 141097040

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01336

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/25/2007 FRAMING Approved IVRS - Inspection :*
06/22/2007 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Items 5 & 8 from prior inspections not done
06/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 4, 5, 6, 8 & 12 FROM 6/18/07 NOT DONE
2) PLUMBING APPROVED IN ERROR ON 6/18/07-NOW DENIED SEE ITEM 5
06/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REDHEAD ANCHOR BOLTS LOOSE IN GARAGE
2) DINING ROOM SMALL SHEARWALL REQUIRES 2 ANCHOR BOLTS
3) STUDS NOT BEARING ON SILL PLATE DINING ROOM
4) BLOCK DUCT BOOTS 3 SIDES
5) KITCHEN TRAP WEIR CANNOT BE HIGHT THAN VENT OPENING
6) SEAL 2ND FLOOR TUB PENETRATIONS
7) NO SECOND FLOOR DWV TEST
8) NO INSULATION BEHIND TUBS
9) MISSING DUCT WORK
10) BLOCK DUCT BOOTS 3 SIDES
11) FIRESTOP STAIRS
12) FIRESTOP 1/2 BATH CHASE
13) OVERSPAN STUD MISSING L/R