Permit: T07CM01330

Parcel: 13734001C


Addresses:

1710 W VALENCIA RD


Inspection Status: Approved

Inspection History: MECHANICAL - ABOVE CEILING

Permit Number - T07CM01330

Inspection Description - MECHANICAL - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2008 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection :*
#300, 400, 700, 800 -- OK FOR TILES
02/11/2008 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection :*
300 - BOOT TAPS TO BE SEALED AND WRAPPED
400 - NO WIRE HANGERS ON DUCT OVER 10"
700 - ROUND TAPS SEALED AND WRAPPED
800 - FLEX SUPPORT NOT TO EXCEED 5'
01/04/2008 MECHANICAL - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
ALL UNLINED DUCT TO BE WRAPPED
SEAL DUCT WHERE NEEDED
INSULATE ALL CONDENSATE PIPING ABOVE CEILING
OK TO ROCK HARD LIDS
01/02/2008 MECHANICAL - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
11/09/2007 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection :*
CONDENSATE PIPING OVERHEAD OK TO INSULATE