Permit: T07CM01320

Parcel: 141310830

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM01320

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/21/2007 FRAMING Approved IVRS - Inspection :*
06/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LVL HEADER TURNED WRONG
2) SHEAR TRANSFER NOT COMPLETE GARGE
3) BANG PLATES ON T & P
4) PLASTER RING AT UFER
5) NOT COMPLETE, NAILING AND CAULKING