| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/04/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) RESULTS OF PRIOR INSPECTION LIKE THE ONE FROM MAY 31, ARE TO BE ON SITE |
|
| 05/31/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING NAILING ON ROOF 2) NEED TRUSS DRAWING 3) TWO NAILS IN ALL WINDBRACES 4) BLOCK UNDER TOWER BEARING 5) REAR TRUSS SHEAR TO GO TO TOP UNLESS IT IS A DRAG STRUT THEN USE A3.5 24" ON CENTER 8) BLOCKING FOR SHEETROCK |