Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/15/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ATTACH LEDGER WITH MINIMUM 3 16D NAILS EACH STUD PER DETAIL. NOT ONE OR 2 IN SOME PLACES |