Permit: T07CM01247

Parcel: 141096150

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/18/2007 FRAMING Approved IVRS - Inspection :*
06/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE INSPECTION 6/14
06/14/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE STOP TUB GARAGE
2) REPLACE WIRE TO ISLAND
3) SUPPORT ABS EVERY 4'
4) FHA STRAPS 3' ABS TOP PLATES
06/11/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) ITEMS FROM 6/6/07 NOT DONE
2) NEXT FAILURE WILL REFEE
06/06/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) DRAFT STOP COMBUSTION AIR INLETS
2) UFER REBAR OUT OF WALL
3) KITCHEN SMALL SHEARWALL 3 REQUIRES 2 ANCHOR BOLTS
4) KITCHEN LARGE SHEARWALL AND REQUIRES 3 ANCHOR BOLTS
5) FIREBLOCK STAIRS
6) SHEAR BLOCKS MISSING AT STAIRS-REMOVE SHINERS
7) FIREBLOCK DUCT CHASES
8) HALL BATH SHEARWALL NOT CONNECTED TO TRUSS PER PLAN
9) NAIL PROTECT PLUMBING
10) FIRESTOP REQUIRES 2 LAYERS OF 1/2" OSB
11) SEAL 2ND FLOOR PENETRATIONS
12) ATTIC ACCESS BLOCKED
13) INSULATE BEHIND TUB ENCLOSURE
14) STOPPED INSPECTION-TO MANY ITEMS
06/05/2007 FRAMING Not ready for Inspection IVRS - Inspection :*