Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01247
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/18/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/15/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE INSPECTION 6/14 |
|
06/14/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE STOP TUB GARAGE 2) REPLACE WIRE TO ISLAND 3) SUPPORT ABS EVERY 4' 4) FHA STRAPS 3' ABS TOP PLATES |
|
06/11/2007 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) ITEMS FROM 6/6/07 NOT DONE 2) NEXT FAILURE WILL REFEE |
|
06/06/2007 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) DRAFT STOP COMBUSTION AIR INLETS 2) UFER REBAR OUT OF WALL 3) KITCHEN SMALL SHEARWALL 3 REQUIRES 2 ANCHOR BOLTS 4) KITCHEN LARGE SHEARWALL AND REQUIRES 3 ANCHOR BOLTS 5) FIREBLOCK STAIRS 6) SHEAR BLOCKS MISSING AT STAIRS-REMOVE SHINERS 7) FIREBLOCK DUCT CHASES 8) HALL BATH SHEARWALL NOT CONNECTED TO TRUSS PER PLAN 9) NAIL PROTECT PLUMBING 10) FIRESTOP REQUIRES 2 LAYERS OF 1/2" OSB 11) SEAL 2ND FLOOR PENETRATIONS 12) ATTIC ACCESS BLOCKED 13) INSULATE BEHIND TUB ENCLOSURE 14) STOPPED INSPECTION-TO MANY ITEMS |
|
06/05/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |