Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01247
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/14/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PORCH BEAM NOT STRAPPED TO COLUMNS |
|
05/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER KEN |
|
05/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 4, 5 FROM 5/9/07 NOT DONE |
|
05/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING REAR PORCH BEAM 2. STRAP NON-OVERLAPPING DOUBLE TOP PLATES 3. CLIP CRIPPLES TO HEADERS 4. 8 FT. SHEAR SEAM NOT NAILED N.E CORNER 5. SHIM HANGERS ADD MISSING HANGERS 6. TRUSSES NOT CLIPPED |