Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01224
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2007 | FRAMING | Approved | IVRS - Inspection :* | |
06/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER B-VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLE MATERIAL 2) PEX PLUMBING REQUIRES 6" CLEARANCE TO B-VENT |
|
06/19/2007 | FRAMING | Partial Approval | IVRS - Inspection :* NO CHANGE FROM PRIOR INSPECTION YOU MUST COMPLY WITH IRC G 24 27.6.4 REFEE |
|
06/18/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) WATER HEATER B-VENT REQUIRES A MINIMUM 30 DEGREE PITCH 2) THIRD FAILURE 3) REFEE |
|
06/15/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TO GET 30 DEGREE PITCH YOU WILL NEED TO LOCATE B-VENT APPROX TO LOCATION OF BLUE X MARKED ON OSB |
|
06/14/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY SUPER |
|
06/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 4, 5 & 6 FROM 6/4/07 NOT DONE 2) WATER HEATER B-VENT MUST HAVE 30 DEGREE PITCH MINIMUM |
|
06/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATHE NOT COMPLETE 2) WIRES CUT 3) NO GAS TEST 4) FIRESTOP REQUIRES LAYERS 1/2" OSB 5) PEX TO CLOSE TO B-VENT 6) FIRESTOP STAIRS 7) BULL NOSE STAIRS 8) NAIL SECOND FLOOR SHEAR PLATE 9) SHEARWALL TOP PLATE NOT NAILED HALL BATH FLOOR |