Permit: T07CM01224

Parcel: 141097030

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/21/2007 FRAMING Approved IVRS - Inspection :*
06/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER HEATER B-VENT REQUIRES 1" CLEARANCE TO COMBUSTIBLE MATERIAL
2) PEX PLUMBING REQUIRES 6" CLEARANCE TO B-VENT
06/19/2007 FRAMING Partial Approval IVRS - Inspection :*
NO CHANGE FROM PRIOR INSPECTION
YOU MUST COMPLY WITH IRC G 24 27.6.4
REFEE
06/18/2007 FRAMING Partial Approval IVRS - Inspection :*
1) WATER HEATER B-VENT REQUIRES A MINIMUM 30 DEGREE PITCH
2) THIRD FAILURE
3) REFEE
06/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO GET 30 DEGREE PITCH YOU WILL NEED TO LOCATE B-VENT APPROX TO LOCATION OF BLUE X MARKED ON OSB
06/14/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BY SUPER
06/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 4, 5 & 6 FROM 6/4/07 NOT DONE
2) WATER HEATER B-VENT MUST HAVE 30 DEGREE PITCH MINIMUM
06/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATHE NOT COMPLETE
2) WIRES CUT
3) NO GAS TEST
4) FIRESTOP REQUIRES LAYERS 1/2" OSB
5) PEX TO CLOSE TO B-VENT
6) FIRESTOP STAIRS
7) BULL NOSE STAIRS
8) NAIL SECOND FLOOR SHEAR PLATE
9) SHEARWALL TOP PLATE NOT NAILED HALL BATH FLOOR