Permit: T07CM01224

Parcel: 141097030

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01224

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/08/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 8 FT SHEARWALL ? NOT NAILED
2) 16/D6 NOT COMPLIED WITH-BUILD TO PLAN
3) 2/D2 NOT COMPLIED WITH
05/07/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) ITEMS 1, 2 & 3 FROM 5/3/07 NOT DONE
2) STOPPED INSPECTION
05/03/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KNEE BRACES MISSING
2) 2 X POSTS FOR GIRDER TRUSS MUST EXTEND THRU CLEAR SPAN
3) BLOCK AND NAIL SHEAR AT 8 FT