Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01224
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 8 FT SHEARWALL ? NOT NAILED 2) 16/D6 NOT COMPLIED WITH-BUILD TO PLAN 3) 2/D2 NOT COMPLIED WITH |
|
05/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) ITEMS 1, 2 & 3 FROM 5/3/07 NOT DONE 2) STOPPED INSPECTION |
|
05/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KNEE BRACES MISSING 2) 2 X POSTS FOR GIRDER TRUSS MUST EXTEND THRU CLEAR SPAN 3) BLOCK AND NAIL SHEAR AT 8 FT 4) STOPPED INSPECTION-TO MANY ITEMS |