Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
| 08/16/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PVC PRIMER MUST ACTUALLY BE APPLIED TO THE PIPE PRIOR TO GLUING. MAKE ALL OTHER CORRECTIONS AS PREVIOUSLY NOTED |
|
| 08/06/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. EXHAUST FAN DUCT SCREW IS BLOCKING THE BACKDRAFT DAMPER. USE ONLY A 1/2" LONG SCREW AND BE SURE IT GOES INTO THE CAVITY ON THE FAN OUTLET DESIGNED FOR A SCREW. SEAL THE EXHAUST DUCT CONNECTION. 2. USE PRIMER ON ALL PVC FITTINGS. RUN THE PVC CONDENSATE STRAIGHT IN THE WALL & SECURE 3. INSULATE SIDE WALL REGISTER BOXES 4. USE FITTINGS TO OFFSET CONDENSATE DRAIN AND USE APPROVED CLAMPS |