Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/11/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* IMPROPER FITTING INSTALLATION AND FOOTING LEDGE USE REMOVABLE TEMP CAPS FOR INSP. |
|
| 06/09/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* PROVIDE LISTING FOR FLANGE EXTENSIONS DN STAIRS OK |
|
| 10/18/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS SEWER OK NEED TO SEE FLANGES |
|
| 10/01/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. NEED TO SEE FIRST FLOOR CLOSET FLANGES 2. OK TO COVER ALL AREAS EXCEPT KITCHEN PONY WALL K.S CLEANOUT NOT APPROVED |
|
| 09/28/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) TWO WAY CLEANOUT MAY NOT BE EMBEDDED IN CONCRETE. USE FRANK PATTERN CLEANOUT COVER OVER CLEANOUTS 2) BLAKE TEE NOT PERMITTED ON IT'S SIDE AS A HORIZONTAL CLEANOUT 3) ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES NO MORE THAN FOUR FEET BETWEEN HANGERS |
|
| 09/21/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 2ND FLOOR CLOSET FLANGES SECURE AND ISOLATE TUBING SECURE ICE MAKER BOX TEST ALL SOLDIER JOINTS IN WALL TEST TUBS TO FLOOD LEVEL SWEEPS REQUIRED ON VENTS BELOW FLOOD LEVEL SEE SEC. 1002.3 LIMITING CHANGE OF DIRECTION OF TRAP ARMS |
|
| 09/19/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* MAY NOT DUMP A DRAIN INTO A VENT |