Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/03/2008 PLUMBING - INTERMEDIATE Approved
05/28/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
LINER OK
STILL NEED PLAN REV. FROM 4/17
05/27/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/23/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SHWR LINER HANDOUT PROVIDED
04/17/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
P-6 & P-1 FIXTURES SPECS CALL FOR STEEL ARM CARRIERS
CLOSET FLANGES OK IF NO TILE
PROVIDE REVISION FOR DELETION OF MS
OK TO COVER
04/16/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PLUMBERS TAPE NOT APPROVED STRAP
2. FINISH INSULATING HOT
3. NO FEMALE THREADS IN UNACCESSIBLE LOCATION
4. ABS WATER TEST THRU ROOF OK
02/27/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CANCELED
02/25/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- PROVIDE TEST ON ALL PIPING
- INSTALL GAUGE ON WATER
- PROVIDE ABV CEILING VALVES PER PLAN
- POSITION VALVES W/CLEARANCE AROUND HANDLE
- PLASTIC FIPS MAY NOT BE CONCEALED
- DRAINAGE FITTINGS REQUIRED ON VENTS BELOW FLOOD LEVEL OF FIXTURE
- SECURE CLOSET FLANGES