Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM01172
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* 1) ALL ITEMS ABOVE CORRECTED, STEAM TABLES HAD ALL ELECTRICAL WIRING REMOVED AND HEATING ITEMS REMOVED |
|
01/17/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* FINAL INSPECTION CORRECTIONS NOT COMPLETED |
|
12/31/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. BOXES IN COMBUSTIBLE OR MORE THAN 1/4" IN NON-COMBUSTIBLE NEED AN APPROVED EXTENDER RING - 314.20 2. PLEASE VERIFY LISTING LABEL FOR FRONT COUNTER EQUIPMENT - HEAT CONTROLS 3. TIGHTEN LOOSE FITTINGS & INSTALL FUSES - ICE MACHINE 4. GROUND HEATER CONTROL ENCLOSURE AND INSTALL A GROUNDING CONDUCTOR IN FLEX 5. PROVIDE BOXES FOR WET LOCATION UNDER DISHWASHER 6. NEED PERMANENT CIRCUIT DIRECTORY PER 400.4 7. EXIT LIGHT NOT WORKING 8. SUPPORT CONDUITS ABOVE PANEL 9. HAVE WILDAN ADD 02090 TO PERMIT 10. PLEASE PROVIDE ACCESS FOR LIGHTS & ROOF 11. KITCHEN RECEPTACLES NOT WORKING |
|
12/03/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
11/29/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* WIRING NOT COMPLETE ABOVE CEILING WILL NEED TO PAY REINSPECTION FEE DO NOT CALL BEFORE COMPLETE |
|
08/27/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* THERE ARE MANY CHANGES TO APPROVED PLANS FOR BRANCH CKT'S, WALLS OK TO COVER SUBJECT TO APPROVAL OF REVISED PLANS. EMERGENCY LIGHTING TO BE FED BY CKT THAT SUPPLIES NORMAL LIGHTING FOR THAT AREA - NEC 700.12F FEEDER TO THIS SPACE SUB-PANEL PULLED BY JAGUAR ELECTRIC & TO BE SEPARATELY PERMITTED. |
|
08/21/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* WIRING NOT PER PLAN IF NEEDED, REVISE PLAN TO SHOW ACTUAL SCOPE OF WORK NO INSPECTION AT THIS TIME |
|
07/17/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK UNDER SLAB RACEWAYS AT BUFFET 3 RECEPTACLES 1 DATA NOTE: PROVIDE SEPARATE RACEWAY TO DATA BOX AND PLUG UNUSED OPENINGS. |
|
07/16/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED |