Permit: T07CM01166

Parcel: 140552920

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/06/2007 FRAMING Approved IVRS - Inspection :*
05/24/2007 FRAMING Partial Approval IVRS - Inspection :*
1) ADD STUDS 2ND FLOOR NEAR STAIRS AND S.E. BEDROOM WHERE BOWED BEYOND STRUCTURAL ALLOWANCES
2) ADD STUD FOR SUPPORT UNDER BOTTOM OF CENTER STRINGER LANDING
05/23/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) HOLDOWNS MISSING NUTS
2) NO DWV WATER TEST
3) SHEARWALL .9 REQUIRES 10D'S AT 2" ON CENTER ENDS AND EDGES
4) PROVIDE DETAIL FOR DBL SHEARWALL 2 CONNECTION TO TRUSS
5) SEAL TEARS IN STUCCO VAPOR BARRIER
6) PROVIDE ELECTRIC OUTLET FOR BAR BUT NOT UNDER OVERHANG
7) SEAL 2ND FLOOR PENETRATIONS AT TUBS
8) FIREBLOCK STAIRS
9) MISSING ANCHOR BOLT SHEARWALL 9
10) STOPPED INSPECTION TO MANY ITEMS