Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM01159
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/17/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO POST TENSION TAG 2) SCREW MISSING DEAD FRONT COVER 3) INSTALL SMOKIE MASTER SITTING 4) COMPLETE COVER BACK FLOW 5) DRYER DAMPER JAMBED SHUT 6) NO FUSES A/C DISCONNECT 7) NEED TALLER LADDER FOR ATTIC ACCESS 8) MARK PLATE ON FURNACE FOR HEAT STRIP 9) NEED PAPERWORK FOR 01025 APPROVAL |