Permit: T07CM01152

Parcel: 21248069E

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
07/06/2007 BUILDING - PROGRESS Approved
06/19/2007 BUILDING - PROGRESS Partial Approval IVRS - Inspection :*
NOTE: THIS INSPECTION COVERS SOUND CURB IN COMPLIANCE WITH SPECIFIC DETAIL ON SHEET M2.0/4 ALSO NEW MECHANICAL, UNIT SUPER FRAMING STEEL WITH 3/16 WELD APPROVED WELD BY SPECIAL INSPECTOR (REPORT PROVIDED) IN REFERENCE AT S1/1 DETAIL

* BUILDING FINAL MUST PROVIDE MECHANICAL FINAL AND ELECTRICAL FINAL IN ACCORDANCE WITH THE SECTION 109.3.10 IBC