Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/25/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* TOOLS ON SITE, JOINT HAVE BEEN RECAULKED PRIOR TO INSPECTION CLOSET FLANGES OK |
|
| 04/21/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* HAVE THE PLUMBER ON SITE AT THE TIME OF THE NEXT INSPECTION - PLUMBER TO HAVE AN INSIDE PACKING IRON, AN OUTSIDE PARKING IRON AND A HAMMER. THE INSPECTOR WILL DEMONSTRATE CORRECT CAULKING TO ANYONE WHO IS INTERESTED. CONTRACTOR TO PAY REINSPECTION FEE |
|
| 04/17/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE 705.1.1 2006 UPC CAULKED JOINTS 2. SEE NOTE #3 FROM 2/12/08 CLOSET FLANGES MUST BE INSTALLED PER CODE ANYTHING ELSE WILL NOT BE APPROVED CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
| 02/19/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. ALL WATER STUB OUTS ARE SUPPORTED OK 2. COMPLETE LIST FROM 2/12/08 |
|
| 02/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER CLASSROOM SINK WALLS ONLY SUBJECT TO APPROVAL OF ARMAFLEX FOR CONDENSATE WASTE INSULATION 2. ALL WATER STUBOUTS TO BE SUPPORTED 3. CLOSET FLANGES TO BE CAULKED PER 2006 UPC CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
| 02/05/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. ALL OPEN SEWER PIPING TO BE PLUGGED AT ALL TIME. NEXT INSPECTION, OPEN DRAINS WILL COST YOU A REINSPECTION FEE 2. ALL HOT RETURN PIPING TO BE INSULATED 3. FLANGES TO BE CAULKED PER 2006 UPC 4. BACK PITCH ON VENT NOT PERMITTED CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
| 02/04/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) TO WET CANNOT INSPECT 2) CAP OFF ALL SEWER PIPING |
|
| 12/20/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLASSROOM SINKS ALONG EXTERIOR WALLS OK TO COVER TO OVERHEAD |