Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/27/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* 1) ALL WALLS TOPPED OUT OK TO GROUT AND CAP |
|
| 11/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG - SOUTH WALL @ 20' - TOPPED OUT EAST WALL @ 20'; EAST BLDG - POPOUT @ 20' OK TO GROUT PROGRESS AREAS |
|
| 11/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG. EAST 1/3 SOUTH WALL @ 16'; EAST WALL @ 16' COMMON WALL @ MIDDLE & EAST BUILDINGS @ 16' MIDDLE BLDG - WEST WALL @ 16' OK TO GROUT PROGRESS AREAS |
|
| 11/15/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BUILDING - SOUTH WALL 14'-18' EXCEPT FOR SE CORNER SECTION - OK TO GROUT PROGRESS AREAS |
|
| 11/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EAST BLDG POP-OUT AT 12'; MIDDLE BLDG SOUTH WALL MID POINT-EAST; WEST WALL TO S.W. CORNER AT 12' WEST BLDG AT S.E. CORNER AT 12'-OK TO GROUT PROGRESS AREAS |
|
| 11/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG - SOUTH WALL MID-POINT WEST @ 12' WEST WALL TO SW CORNER @ 8' WEST BLDG SE CORNER @ 8' OK TO GROUT PROGRESS AREAS |
|
| 11/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG - SOUTH WALL; WEST CONTROL JOINT TO EAST WRAP-AROUND @ 4'8" OK TO GROUT |
|
| 10/31/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG - SOUTH WALL @ 4' - OK TO GROUT |
|
| 10/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP EAST BLD OK |
|
| 10/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST BLDG PERIMETER WALLS @ 20' - EXCEPT FOR SE CORNER; MIDDLE BLDG - NORTH WALL @ 18'4" OK TO GROUT PROGRESS AREAS |
|
| 10/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BUILDING PERIMETER WALLS @ 18'4" - EXCEPT SW CORNER - OK TO GROUT |
|
| 10/22/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* - WEST BUILDING: PERIMETER WALLS @ 16' - EXCEPT FOR SE CORNER - MIDDLE BUILDING: NORTH WALL MID-POINT TO EAST @ 16' - LINTEL BETWEEN MIDDLE & EAST BLDG @ 16' - OK TO GROUT PROGRESS AREAS |
|
| 10/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG: NORTH WALL MID-POINT EAST; EAST WALL @ 12' EAST BLDG: PERIMETER WALLS @ 12' (EXCEPT SW CORNER) OK TO GROUT PROGRESS AREAS |
|
| 10/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG; NORTH WALL (MID-POINT WEST) @ 12' WEST BLDG. PERIMETER WALLS EXCEPT SE CORNER @ 12' OK TO GROUT |
|
| 10/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG. MIDPOINT EAST @ 12' EAST WALL AT 12' EAST BLDG. PERIMETER WALLS @ 12' EXCEPT FOR SW CORNER -- OK TO GROUT |
|
| 10/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MIDDLE BLDG, NORTH WALL (MID.POINT TO WEST WALL) WEST WALL TO SW CORNER @ 8' WEST BLDG. PERIMETER WALLS @ 8' EXCEPT FOR SE CORNER OK TO GROUT PROGRESS AREAS |
|
| 10/03/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BLDG, PERIMETER WALLS @ 8' EXCEPT FOR SW CORNER OK TO GROUT |
|
| 09/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* - WEST BLDG. ALL WALLS EXCEPT SE CORNER @ 4' - MIDDLE BLDG. MIDPOINT TO WEST, WEST WALL, EAST WALL @ 4' - OK TO GROUT PROGRESS AREAS |
|
| 09/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BUILDING PERIMETER WALLS @ 4'; MIDDLE BUILDING (NORTH WALL - CENTER PORTION TO EAST WALL) @ 4' GROUTED - SPECIAL INSPECTED |
|
| 08/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BUILDING STEM WALL @ 24" CONTINUOUS OK TO GROUT |
|
| 08/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM WALLS - WEST BUILDING & MIDDLE BLDG @ 0"-40" OK TO GROUT PROGRESS AREAS |