Permit: T07CM01130

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T07CM01130

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
05/11/2009 PLUMBING - SEWER HCS CONNECT Approved
08/08/2008 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
COMPLETE LIST #1 FROM 8/6/08
08/06/2008 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
1) PROVIDE RED LINE DRAWINGS FOR COOL AND DRAIN TO BE APPROVED BY CITY OF TUCSON AT LATER DATE
2) PROVIDE SUPPORT ON ALL PIPING
3) REPAIR LEAK ON 2ND FLOOR AND RETEST
4) INSULATE PER KEY NOTES
08/05/2008 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
TEST TO HOLD WITH NO LEAKAGE. PROVIDE THIN WALL PVC BUSHING PRIMED & GLUED ON TO SDR35 WITH APPROVED MISSION STYLE PLASTIC X PLASTIC COUPLING. PROVIDE GREEN TRACER WIRE ON SEWER.
08/01/2008 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
ALL PIPING TO BE SUPPORTED AT CORRECT INTERVALS WITH APPROVED METHODS WITH TEST IN PLACE AT TIME OF INSPECTION